Experimental study on repair of cracked pipe under internal pressure
DOI:
https://doi.org/10.21533/pen.v10.i6.909Abstract
Repair of cracked pipeline under internal pressure has been investigated in the present study. To this aim, an experimental test has been done on the cracked pipeline to find failure pressure. A longitudinal crack that cut 65% thickness of pipe has been applied on the external surface. Carbon fiber reinforced polymer has been used to repair the system. Additionally, a finite element model has been developed to estimate failure pressure of the unrepaired pipes. The results show that the failure pressure in unrepaired pipes is identical to the failure pressure predicted by the standards for corroded pipes, however, the failure pressure of repaired system is lower than the predicted results of standard for corroded pipelines.
Downloads
Published
Issue
Section
License

This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.