Artificial extension for a canine with partial forelimb amputation

Arly Dario Rincón-Quintero, Gianina Garrido Silva, Jessica Gissela Maradey Lázaro, Edwin Francisco Forero García, Camilo Leonardo Sandoval Rodríguez

Abstract


When a canine presents a serious case of disease, injury or necrosis, it is imperative to perform an amputation procedure, whatever the affected limb is, since it can minimize the risk of developing pathologies related to tissues, joints and spine, associated with an altered gait and/or unequal distribution of forces in their limbs. Thus, improvement alternatives arise such as prostheses which help to improve the quality of life of canines. The article proposes the development of a functional prototype of prosthesis for canines with partial forelimb amputation through the design and 3D modeling of the prosthesis, together with the selection of the material that adapts to the morphological conditions of the canine. Also, a cushioning system is incorporated to minimize the force of the impact with the ground when performing activities such as jumping, running or walking. Finally, the electronic component is included in the design and the respective electronic and biomechanical tests are carried out to verify its correct operation.

Keywords


Amputation, canine, exoprosthesis

Full Text:

PDF

References


M. Á. Pardo Jiménez, “Diseño de una prótesis canina para extremidades delanteras,” 2017.

J. G. M. Lazaro, A. D. R. Quintero, C. L. S. Rodriguez, O. L. Perez, and J. F. C. Hernandez, “Design And Set Up Of A Pulverized Panela Machine,” Period. Eng. Nat. Sci., vol. 9, no. 4, pp. 812–828, 2021.

C. L. Sandoval-Rodríguez, E. A. C. Quintana, B. E. T. -Romero, A. D. Rincón-Quintero, and J. G. Maradey-Lazaro, “Characterization of mechanical vibrations in a metal structure using the transform Cepstrum,” Period. Eng. Nat. Sci., vol. 9, no. 4, pp. 767–777, 2021.

G. Garrido-Silva, J. Maradey Lazaro, A. Rincón-Quintero, O. Lengerke Perez, C. Sandoval Rodriguez, and C. Cardenas-Arias, “Estimation of the Energy Consumption of an Electric Utility Vehicle: A Case Study,” in Recent Advances in Electrical Engineering, Electronics and Energy Vol.2, 2021, pp. 257–272.

M. C. Camacho, Y. R. Gallardo, R. C. Stegun, B. Costa, and N. Sesma, “Behavior of mandibular canines as abutment teeth and indirect retainers in Kennedy class II Removable Partial Denture Prosthesis,” Heliyon, vol. 4, no. 3, p. e00575, 2018.

A. D. Rincón-Quintero, L. A. Del Portillo-Valdés, A. Meneses-Jácome, C. L. Sandoval-Rodríguez, W. L. Rondón-Romero, and J. G. Ascanio-Villabona, “Trends in Technological Advances in Food Dehydration, Identifying the Potential Extrapolated to Cocoa Drying: A Bibliometric Study,” in Recent Advances in Electrical Engineering, Electronics and Energy Vol.2, M. Botto Tobar, H. Cruz, and A. Díaz Cadena, Eds. Cham: Springer International Publishing, 2021, pp. 167–180.

C. Sabater, “Diseño y cálculo de una prótesis canina,” 2019.

B. E. T. Romero, A. C. Celador, C. L. S. Rodriguez, J. G. A. Villabona, and A. D. R. Quintero, “Design and construction of a solar tracking system for linear fresnel concentrator,” Period. Eng. Nat. Sci., vol. 9, no. 4, pp. 778–794, 2021.

A. Rincón-Quintero, O. Lengerke Perez, J. Maradey Lazaro, G. Garrido-Silva, C. Sandoval Rodriguez, and J. Osorio-Lizarazo, “Determination of Heat Transfer Coefficients in Natural and Forced Convection for Different Geometric Configurations, Using a Prototype Controlled by LabView Software and Arduino Hardware,” in Recent Advances in Electrical Engineering, Electronics and Energy Vol.1, 2021, pp. 223–237.

V. D. Samrit, N. Wadhawan, O. P. Kharbanda, and R. Duggal, “Interdisciplinary management of a complicated case of bilaterally impacted maxillary canines and missing lateral incisors with canine-premolar transposition: A 10-year follow-up,” AJO-DO Clin. Companion, vol. 00, no. 00, pp. 1–12, 2022.

M. J. Day, S. J. Butterworth, M. R. Palmer, and C. P. Case, “Characterization of wear debris associated with aseptic loosening of a canine hip prosthesis,” J. Comp. Pathol., vol. 119, no. 1, pp. 89–93, 1998.

J. G. M. Lázaro and C. L. S.- Rodríguez, “Design and set up of a pulverized panela machine,” vol. 9, no. 4, pp. 812–828, 2021.

A. D. Rincón-Quintero, L. A. Del Portillo-Valdés, A. Meneses-Jácome, J. G. Ascanio-Villabona, B. E. Tarazona-Romero, and M. A. Durán-Sarmiento, “Performance Evaluation and Effectiveness of a Solar-Biomass Hybrid Dryer for Drying Homogeneous of Cocoa Beans Using LabView Software and Arduino Hardware,” in Recent Advances in Electrical Engineering, Electronics and Energy Vol.1, M. Botto Tobar, H. Cruz, and A. Díaz Cadena, Eds. Cham: Springer International Publishing, 2021, pp. 238–252.

P. Canallatos, T. Mclean, J. Frustino, J. Zemer, A. Colebeck, and M. Sullivan, “Maxillary resection prosthesis fabricated from urethane dimethacrylate for a patient with polymethyl methacrylate allergy: A clinical report,” J. Prosthet. Dent., pp. 1–4, 2022.

C. Cardenas-Arias, C. Sandoval Rodriguez, A. D. Rincón-Quintero, D. Galván, and H. Téllez, “Data Collector Design for Vibration Analysis by Raspberry pi 3B Embedded System Means for Industrial Applications Data Collector Design for Vibration Analysis by Raspberry pi 3B Embedded System Means for Industrial Applications,” J. Phys. Conf. Ser., vol. 2224, 2022.

K. D. Mendoza-calderón, J. Andres, and M. Jaimes, “Design of an Automatic Palletizer,” J. Phys. Conf. Ser., vol. 2224, 2022.

A. D. Rincón-Quintero et al., “Manufacture of hybrid pieces using recycled R-PET, polypropylene PP and cocoa pod husks ash CPHA, by pneumatic injection controlled with LabVIEW Software and Arduino Hardware,” IOP Conf. Ser. Mater. Sci. Eng., vol. 844, no. 1, 2020.

M. A. Wirth, D. L. Korvick, C. J. Basamania, F. Toro, T. B. Aufdemorte, and C. A. Rockwood, “Radiologic, mechanical, and histologic evaluation of 2 glenoid prosthesis designs in a canine model,” J. Shoulder Elb. Surg., vol. 10, no. 2, pp. 140–148, 2001.

N. Bergknut et al., “The performance of a hydrogel nucleus pulposus prosthesis in an ex vivo canine model,” Biomaterials, vol. 31, no. 26, pp. 6782–6788, 2010.

N. Ru and Y. Bai, “Canine autotransplantation: Effect of extraction site preservation with a titanium prosthesis and a bioresorbable membrane,” Am. J. Orthod. Dentofac. Orthop., vol. 143, no. 5, pp. 724–734, 2013.

Y. qin Pan et al., “The use of CT scan and stereo lithography apparatus technologies in a canine individualized rib prosthesis,” Int. J. Surg., vol. 12, no. 1, pp. 71–75, 2014.




DOI: http://dx.doi.org/10.21533/pen.v11i1.3178

Refbacks

  • There are currently no refbacks.


Copyright (c) 2023 Arly Dario Rincón-Quintero, Gianina Garrido Silva, Jessica Gissela Maradey Lázaro, Edwin Francisco Forero García, Camilo Leonardo Sandoval Rodríguez

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.

ISSN: 2303-4521

Digital Object Identifier DOI: 10.21533/pen

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License